Gas Chromatograph GC-901

  • Model : GC-901
  • Oven Temp. Accuracy : ≤±0.01℃
  • Oven Temp. Program : 16-phase
  • Oven Time Range : 0-999.9min
  • Size(W×D×H)(mm) : 560x560x485

Share the product

GC-901 gas chromatograph can realize full EPC electronic flow control, realize full computer control of the instrument, and can be equipped with a high-precision liquid automatic sampler. It can be widely used in many fields such as petroleum, chemical industry, environmental protection, food safety, disease control, education and scientific research, and can analyze the macro, micro and trace amounts of organic matter, inorganic matter and gas.

Gas Chromatograph Feature:

  1. Using resistive touch screen, touch button design is unique
  2. Humanised software operating system
  3. Support long-distance transmission, remote control and remote diagnosis.
  4. High-precision gas flow control system (EPC)
  5. Advanced feeder design, unique liner structure and special processing technology to ensure zero sample adsorption
  6. Timed self-starting procedure for easy on-line analysis of laboratory gas and liquid samples.

Gas Chromatograph Specification:

Model GC-901
Oven Temp. Range RT+5~450℃
Temp. Accuracy ≤±0.01℃
Temp. Program 16-phase
Max. Temp. Heating Rate 40℃/min
Time Range 0-999.9min
Detector Hydrogen Flame Ionization Detector (FID) Detection limit: ≤5×10-12g/s (100ng/ul n-hexadecane-isooctane solution)
Temperature 450℃
Compatible with packed and capillary columns
Baseline drift: ≤2×10-13A/30min
Baseline noise: 3×10-14A
Dynamic range: ≥107
Thermal Conductivity Detector (TCD) Sensitivity: >5000mv.ml/mg (50mg/ml toluene-benzene solution)
Temperature 400℃
Baseline drift: ≤0.1mV/30min
Baseline noise: 0.03mV
Dynamic range: ≥105(±10%)
Electron Capture Detector (ECD) Detection limit: ≤1×10-14g/ml (Sample: n-hexadecane δ-666)
Dynamic range: ≥104
Flame Photometric Detector (FPD) Detection limit: ≤5×10-12g/s (S of 10ng/uL methyl parathion-ethanol solution)
Detection limit: ≤4×10-12g/s (P of 10ng/uL methyl parathion-ethanol solution)
Dynamic range: ≥S 103
Dynamic range: ≥P 104
Temperature 350℃
Nitrogen and Phosphorus Detector (NPD) Detection limit: ≤1×10-12g/s (Azobenzene)
Detection limit: ≤1×10-12g/s (Marla sulfur phosphorous)
Dynamic range: ≥103
Injection Method Capillary column split/splitless sampling (with diaphragm purging function), packed column sampling, valve sampling, gas/liquid automatic sampling system, etc.
Inlet 1~4, up to 3 capillary column inlets
Injection Type Packed column injection, capillary column injection. (Flow setting range: 0~1000ml/min)
Control Accuracy Pressure: 0.01KPa; Flow: 0.01ml/min
Maximum Split Ratio 0.735416667
Pressure Sensor Accuracy: <2% of full scale;
Repeatability: <± 0.05KPa;
Range: 0~0.6MPa
Flow Sensors Accuracy: < 5% of full scale;
Repeatability: 0.5K Pa (full scale);
Output offset (accuracy): ±5%
Sampling Valve Can be equipped with multiple imported automatic control valves, which can run automatically in sequence
Power Supply AC220V±10%, 50/60Hz
Standard Accessory FID detector, Chromatography workstation software, Capillary sampler
Optional Accessory Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column.
Sizes(W×D×H)(mm) 560x560x485
Shipping Size (W×D×H)(mm) 780x750x750
N.W./G.W. (kg) 50/75